BFOU power cables have a mica glass tape wrapped around the conductor to provide circuit integrity for 3 hours when exposed to fire in accordance with IEC 60331-21. Designed to NEK606 and IEC 60092-353 BFOU meets the most stringent fire resistant, flame retardant and low smoke emission tests. It is the perfect choice for low voltage power and control applications on rigs, ships and FPSO applications.
Voltage Rating:Conductor Stranding:Current Rating:Temperature Rating:Bending Radius Static:Oxygen Index of Sheath:Fire Resistant:Flame Retardant:Smoke Emission:Halogen Emission:MUD Resistant:Manufactured To:3rd Party Approval:
0.6/1kVIEC 60228 Class 2, tinned copperFEA-M clause 1881.5 – 11 or IEE regs. table 4H2A+B depending on application-40°C to +85°C6 x overall diameter>31%IEC 60331-21IEC 60332-1-2, IEC 60332-3-22 Cat AIEC 61034-1 & 2IEC 60754-1 & 2NEK 606 P5/P12IEC 60092-353, NEK 606DNV, approvals may vary between manufacture brands.
Tinned stranded copper conductor, mica glass tape fire barrier, EPR insulation, halogen free thermoplastic elastomeric bedding, tinned copper wire braid armour, MUD resistant LSHF elastomeric outer sheath.The cross sectional area (mm2) of the screen is shown after the conductor size in the table below.
1 Core2 Cores3 Cores4 Cores5 Cores and above
BlackLight grey, blackLight grey, black, redLight grey, black, red, bluenumber coded
Flexible & Specialist Cables, Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX