BFOU instrumentation cables are designed to meet the needs of circuit integrity installations within the offshore industry. manufactured to IEC 60092-3 & NEK606, they are available as collectively or individually screened options for optimum EMI screening. Fire barrier tapes are combined with Low Smoke Halogen Free sheath to provide uninterrupted communications during a fire. BFOU cables are resistant to MUD and drilling oils and meet the flame retardance requirements of IEC 60332-3-22 Cat A.
Voltage Rating:Conductor Stranding:Temperature Rating:Bending Radius Static:Oxygen Index Of Sheath:Fire Resistant:Flame Retardant:Smoke Emission:Halogen Emission:MUD Resistant:Manufactured To:3rd Party Approval:
250VIEC 60228 Class 2, tinned copper-40°C to +85°C 6 x overall diameter>31%IEC 60331-21 IEC 60332-1-2IEC 60332-3-22 Cat AIEC 61034-1 & 2IEC 60754-1 & 2NEK606 Collective Screen S4/S8Individual Screen S3/S7IEC 60092-376NEK606DNV, approvals may vary between manufacture brands.
Tinned stranded copper conductor, mica tape, EPR insulation, overall screen of copper backed polyester tape with a stranded copper drain wire, inner sheath of halogen free elastomeric, tinned copper wire braid armour, MUD resistant - LSHF elastomeric sheath. The individually screened version has a copper backed polyester tape with a stranded copper drain wire around each pair or triple.
Conductor Size:Conductor Resistance:L/R Ratio:Mutual Capacitance @ 800Hz:Collective Screen:Individual Screen:
0.75mm² <26.7 Ohms/km12.7mH/Ohm100nF/km110nF/km
1.5mm²<13.7 Ohms/km26.6mH/Ohm110nF/km125nF/km
PairsTriples
Light blue, black and numberedLight blue, black, brown and numbered
Other pair and triple configurations available on request.
2.5mm2 conductor sizes are available in some sizes, please contact us for more information.