Fire resistant instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Mica glass tape fire barriers provide circuit integrity whilst the oil resistant SW4 Low Smoke Halogen Free sheathing compound ensures protection to both people and property during a fire.
Voltage Rating:Conductor Stranding:Temperature Rating:Bending Radius Static:Oxygen Index of Sheath:Fire Resistant:Flame Retardant:Smoke Emission:Halogen Emission:Oil Resistant:Manufactured To:
150/250VIEC 60228 Class 2,tinned copper-30°C to +85°C8 x overall diameter>31%IEC 60331-21IEC 60332-1-2IEC 60332-3-22 Cat AIEC 61034-1 & 2BS 7622IEC 60754-1 & 2BS 6425-1BS 7655 SW4 section 2.6BS 7917/UKOOA
Collectively ScreenedTinned copper wire conductors to IEC 60228 class 2, mica glass tape fire barrier EPR insulation, cores twisted into pairs or triples, overall foil screen and drain wire, SW4 oil resistant LSHF sheath - grey, blue or black.Individually ScreenedTinned copper wire conductors to IEC 60228 class 2, mica glass tape fire barrier, EPR insulation, cores twisted into pairs or triples, each pair aluminum foil screened with a drain wire, SW4 oil resistant LSHF sheath – grey, blue or black.Class 5 conductors to IEC 60228 can be supplied on request.
Conductor Size:Conductor Resistance:Insulation Resistance:Mutual Capacitance @ 800Hz:Collective Screen:Individual Screen:
0.75mm² <24.5 Ohms/km940 MOhm x km80nF/km90nF/km
1.5mm²<12.1 Ohms/km730 MOhm x km90nF/km110nF/km
Pairs - Triples -
Black & whiteBlack, white & red
Each pair is identified by a numbered tape or printed numbers on the cores.
Other pair and triple configurations available on request.
Flexible & Specialist Cables, Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX