Profibus DP IEC 61158 / EN 50170 SINEC L2

A range of single pair bus cables for process and field communication in cell networks. The Profibus protocol has been widely adopted for production and process automation applications providing transmission rates up to 12Mbits.

Static cables

Plain copper conductors 0.64mm (22AWG), foamed PE with a hard skin insulation, synthetic bedding, aluminium foil screen & tinned copper wire braid – 60% optical coverage, thermoplastic or thermosetting sheath.

Technical Information

Core identification Red & Green
Operating temperature -40°C to +60°C
Voltage Working : 100V
Impedance 150 Ω
Effective capacitance @ 1khz 28.5nF/m
Velocity of propagation 78%
Nominal attenuation MHz
4
9.6
16
dB/100m
22.0
2.5
42.0

Dynamic cables

Plain copper conductors 0.25mm² Foamed PE with a hard skin insulation, cores laid up with fillers and a polyester tape, aluminium foil screen & tinned copper wire braid – 60% optical coverage, polyurethane (PUR) sheath.

Technical Information

Core identification Red & Green
Operating temperature -40°C to +60°C
Voltage Working : 100V
Impedance 150 Ω /km
Effective capacitance @ 1khz 28.5nF/m
Velocity of propagation 78%
Nominal attenuation MHz
4
9.6
16
dB/100m
25.0
3.0
53.0

 

Technical Data

Part No.
Belden
No.
Conductor
Stranding
Conductor
Resistance
Sheath
Material
Sheath
Colour
FastConnect
/Quickstrip ?
Weight
Kg/Km
O/D
mm
Application
  2201PODF    3079A   Solid   57.1   PVC   Violet    Yes    148   8.0   Static  
  2201PODFH    LSHF    Solid   57.1   LSHF   Violet    Yes    152   8.0   Static  
  2201PODFD    DUCT   Solid   57.1   PE   Black    No    213   9.5   Wet/outdoor static 
  2201PODFA    SWA   Solid   57.1   PE   Black   Yes   289   11.9   Static 
  2201PODF-HF    Hi-FLEX   Fine    84.0   PUR   Violet    No    172   8.6   Dynamic  
  2201PODF7    3079E   7 Str   59.4   PVC   Violet    No    149   8.0   Euro type static 
  2201PODF-HT    Hi-TEMP*   Solid   57.1   FEP   Violet    No    64   7.2   High Temperature 

* Call our sales team for more details on the high temperature version or other Siemens style cables.

At FSC we refer to LSHF as Low Smoke Halogen Free

This term is interchangeable with LSZH (Low Smoke Zero Halogen), LSOH (Low Smoke Zero Halogen), OHLS (Zero Halogen Low Smoke) and FRNC (Flame Retardant Non-Corrosive). Beware of the terms LSF (Low Smoke and Fume) or RP (Reduced Propogation), when relating to signal or control cables will normally be modified PVC and produce 'Loads of Smoke and Fume'!

Fire retardant, fire resistant, flame resistant or flame retardant?

These terms are often misunderstood. Most cables when exposed to fire will not carry on functioning. If you require cable to continue working in the event of fire, and in accordance with various standards please call us.

 

 

 

 

 

 

 

 

 

 

 

 

 

Some common mispellings of Belden Cable include - Beldon, Beldan, Balden, Baldon and Beldin.