Audio/Visual/Data Cables 22AWGThese cables are used extensively within security,
computer and instrumentation applications. Many sizes are also used within
the audio field as snake cables where the individually screening of pairs
reduces cross talk. The 3 pair version is particularly popular with the
security industry for CCTV and access control.
|
ConstructionTinned copper conductor 22(7) AWG, 0.35 mm². polypropylene
insulated, colour chart 3. Twisted into pairs,
each pair aluminium/polyester foil screened, tinned copper drain wire
(24AWG), PVC sheath on standard cables. UL Style 2919 300V 80°C. Nominal
Impedance 50 Ohms.
|
![]() |
Technical Data |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| All the types listed are normally available from stock
and not subject to minimum order quantities. Alternative coloured jackets can be produced to meet your specific needs. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
UL style numbers are given for cross reference purposes only - not all the cables in this section are tested or approved by UL. If you require UL approved versions please tell us when you first enquire. At FSC we refer to LSHF as Low Smoke Halogen FreeThis term is interchangeable with LSZH (Low Smoke Zero
Halogen), LSOH (Low Smoke Zero Halogen), OHLS (Zero Halogen Low Smoke)
and FRNC (Flame Retardant Non-Corrosive). Beware of the terms LSF (Low
Smoke and Fume) or RP (Reduced Propogation), when relating to signal or
control cables will normally be modified PVC and produce 'Loads of Smoke
and Fume'!
Fire retardant, fire resistant, flame resistant or flame retardant?These terms are often misunderstood. Most cables when
exposed to fire will not carry on functioning. If you require cable to
continue working in the event of fire, and in accordance with various
standards please call us. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||