Unscreened Data Cables

General purpose unscreened data cables with a small outer diameter, frequently used in audio, data, security and instrumentation applications.

Voltage :

22AWG cables : 300V
20AWG cables : 300V
18AWG cables : 300V
16AWG cables : 300V
14AWG cables : 600V

 

Construction

Tinned copper stranded conductor, PVC insulation on standard cable, twisted up as cores or pairs, grey PVC sheath. On the LSHF versions, the insulation and sheath materials are changed to ones that do not emit halogens.

Technical Data

Part No.
Belden
No.
No. of
Pairs
AWG
CSA
mm²
Weight
Kg/Km
O/D
mm
Core
Colours
Capacitance
pF/m

 Pairs Unscreened

  2201PUY    8442   1   22(7)   0.35   23   4.5   Black/Red   99 
  2201PUYH    LSHF   1   22(7)   0.35   23   4.5   Black/Red   99 
  2001PUY    8205   1   20(7)   0.56   26   5.0   Black/Red   81 
  2001PUYH    LSHF   1   20(7)   0.56   26   5.0   Black/Red   81 
  1801PUY    9740   1   18(16)   0.79   37   6.0   Black/Red   84 
  1801PUYH    LSHF   1   18(16)   0.79   37   6.0   Black/White   84 
  1601PUY    8471   1   16(19)   1.23   56   7.0   Black/White   108 
  1601PUYH    LSHF   1   16(19)   1.23   56   7.0   Black/White   108 
  1401PUY    8473   1   14(42)   2.01   89   8.5   Black/White   108 
  1401PUYH    LSHF   1   14(42)   2.01   89   8.5   Black/White   108 
  2202PUYH    9744 NH   2   22(7)   0.35   39   6.2   Chart 3   83 
  1802PUYH    9156 NH   2   18(16)   0.79   71   8.5   Chart 3   84 
  2003PUY    9750   3   20(7)   0.56   67   7.6   Chart 3   80 
  2003PUYH    LSHF    3   20(7)   0.56   67   7.6   Chart 3   80 
Part No.
Belden
No.
No. of
Cores
AWG
CSA
mm²
Weight
Kg/Km
O/D
mm
Core
Colours
Capacitance
pF/m

 Multicore Unscreened

  2203CUY    9491   3C   22(7)    0.35   32   4.9   Chart 2    85 
  2204CUYH    8444 NH   4C   22(7)   0.35   34   5.1   Chart 2   111 
These cables can also be supplied in SWA versions for direct burial

UL style numbers are given for cross reference purposes only - not all the cables in this section are tested or approved by UL. If you require UL approved versions please tell us when you first enquire.

At FSC we refer to LSHF as Low Smoke Halogen Free

This term is interchangeable with LSZH (Low Smoke Zero Halogen), LSOH (Low Smoke Zero Halogen), OHLS (Zero Halogen Low Smoke) and FRNC (Flame Retardant Non-Corrosive). Beware of the terms LSF (Low Smoke and Fume) or RP (Reduced Propogation), when relating to signal or control cables will normally be modified PVC and produce 'Loads of Smoke and Fume'!

Fire retardant, fire resistant, flame resistant or flame retardant?

These terms are often misunderstood. Most cables when exposed to fire will not carry on functioning. If you require cable to continue working in the event of fire, and in accordance with various standards please call us.

 

 

 

 

 

 

 

 

 

 

 

 

 

Some common mispellings of Belden Cable include - Beldon, Beldan, Balden, Baldon and Beldin.


Back to last page Return to TOP