Access Control

Specifically designed for proprietary access control systems, this cable has Low Smoke and Halogen Free cores and jacket. Widely used in public buildings including hospitals, government and local authority offices as well as commercial and retail organisations where security and safety are important. The Low Smoke Halogen Free construction ensures minimum risk in the event of fire to both property and personnel.
    

Construction - 3993P9CHP

Pair 1 :
1 twisted pair 20(7)AWG tinned copper strands, foam PE insulation, 20(7)AWG tinned copper drain wire, aluminium/polyester foil. Colour code: black/green.
Pairs 2 & 3 :
Twisted pairs 22(7)AWG tinned copper strands, foam PE insulation, 22(7)AWG tinned copper drain wire, each individual pair aluminium/polyester foil screened pair. Colour code: black/red & black/white.
Cores :
9 single cores 22(7)AWG tinned copper wire strands, solid Polypropylene insulation. Colour code: black, white, red, green, brown, blue, orange, yellow, purple.
Overall Screen :
Aluminium/polyester foil, 22(7)AWG tinned copper drain wire.
Sheath :
Low Smoke Halogen Free colour purple.

Technical Data

Part No.
Weight
Kg/Km
O/D
mm

 Composite Access Control

 3993P9CHP   114   9.1 

Additional cables used for access control systems

Part No.
Belden
No.
No. of
Pairs
AWG
Screen
Type
Weight Kg/Km
OD
mm
Protocol

 Bus Wiring & Door Release

 1601PUY   8471   1   16   Unscreened   56   7.0   Echelon  
 1601PUYH   8471NH   1   16   Unscreened   56   7.0   Echelon  

 Access Control

 2202PIFR   8723   2   22   Individual foils    32   4.2   Traditional security 
 2202PIFRH   8723NH   2   22   Individual foils   32   4.2   Traditional security 
 2203PIFR   8777   3   22   Individual foils    32   7.0   Traditional security 
 2203PIFRH   8777NH   3   22   Individual foils    32   7.0   Traditional security 
 2402POHP   9842   2   24   O/A foil & braid    95   8.6   RS-485 
 2402POHPH   9842NH   2   24   O/A foil & braid    95   8.6   RS-485 
 2803POHPH   8133   3   28   O/A foil & braid    52   6.8   RS-485 

At FSC we refer to LSHF as Low Smoke Halogen Free

This term is interchangeable with LSZH (Low Smoke Zero Halogen), LSOH (Low Smoke Zero Halogen), OHLS (Zero Halogen Low Smoke) and FRNC (Flame Retardant Non-Corrosive). Beware of the terms LSF (Low Smoke and Fume) or RP (Reduced Propogation), when relating to signal or control cables will normally be modified PVC and produce 'Loads of Smoke and Fume'!

Fire retardant, fire resistant, flame resistant or flame retardant?

These terms are often misunderstood. Most cables when exposed to fire will not carry on functioning. If you require cable to continue working in the event of fire, and in accordance with various standards please call us.

 

 

 

 

 

 

 

 

 

 

 

 

 

Some common mispellings of Belden Cable include - Beldon, Beldan, Balden, Baldon and Beldin.