Draka FT Data Cable

code: F1176

  • High performance fire survival data cable
  • High speed data transfer approaching Cat 5E
  • Provides circuit integrity to critical systems in the event of fire
  • London Underground Approved

Firetuf Data is a group of high performance fire survival data cables manufactured by Draka and designed to carry on functioning even in the event of a fire. This allows safe monitoring of evacuation routes without putting lives at risk.

The twisted pair cables provide high data transmission rates and have been developed to mimic Cat 5E cabling as closely as possible. Increasingly popular with system integrators for BMS applications, the cables can be terminated using traditional LAN Insulation Displacement Connectors (IDC) making them ideal for use in horizontal backbone wiring systems in offices and public buildings.

Where people and property come first the Draka Firetuf Data cable range provides the ideal solution.


Image representative of product style, product supplied may vary.
22(1)AWG solid plain copper conductor, PE/silicone rubber composite insulation, cores twisted into pairs, pairs laid up, woven glass tape, aluminium screen in contact with stranded tinned copper drain wire, tinned copper wire braid, Low Smoke Halogen Free sheath - red.

Designed generally to ISO/IEC 11801:95, EN 50173 95 and EN 50288-2-1. Suitable for standard insulation displacement connector L.A.N. sockets. RS-485 10Mb/s.
Flame Retardant: IEC 60332-1-2
EN 60332-1-2
IEC 60332-3-24C
EN60332-3-24C
BS 4066 Part 3
Smoke Emission: IEC 61034-2
EN 61034-2
BS EN 50268-2
Halogen Emission: IEC 60754-1
EN 50267-2-1
IEC 61034-2
EN 50267-2-2
LU 1-085 A2
Colour Code: Chart 5 (Western Electric)

CFS-TCWB - Collective Foil Screen, Tinned Copper Wire Braid
BS 5839 Clause 26.2E >2hrs @ 950°C
BS 6387 >3hrs @ 950°C
IEC 60331-23 >3hrs @ 750°C
BS EN 50200 >3hrs @ 950°C
BS EN 50200:2000
BS 8438-2:2003
BS 8438-2 Class PH120 120 minutes
BS 5839-1 2002+A2 2008
LU 1-085-A2 fire safety performance of materials. Approved for use below ground without restriction.

Order by 4.30pm for delivery by

Code Description Approval AWG mm mm² No. Pairs Screen Colour Sheath Brand Downloads
387FTD103
1 x 2 x 0.63mm Firetuf Data BS5839 IEC60331-2 Red LSHF
LU 22 0.63 0.34 1 Overall Foil & Braid Red LSHF Draka Get Quote
Description 1 x 2 x 0.63mm Firetuf Data BS5839 IEC60331-2 Red LSHF
Approval
AWG LU
mm
mm² 22
No. Pairs
Screen
Colour
Sheath 0.63
Brand 0.34
387FTD203
2 x 2 x 0.63mm Firetuf Data BS5839 IEC60331-2 Red LSHF
LU 22 0.63 0.34 2 Overall Foil & Braid Red LSHF Draka Get Quote
Description 2 x 2 x 0.63mm Firetuf Data BS5839 IEC60331-2 Red LSHF
Approval
AWG LU
mm
mm² 22
No. Pairs
Screen
Colour
Sheath 0.63
Brand 0.34
387FTD403
4 x 2 x 0.63mm Firetuf Data BS5839 IEC60331-2 Red LSHF
LU 22 0.63 0.34 4 Overall Foil & Braid Red LSHF Draka Get Quote
Description 4 x 2 x 0.63mm Firetuf Data BS5839 IEC60331-2 Red LSHF
Approval
AWG LU
mm
mm² 22
No. Pairs
Screen
Colour
Sheath 0.63
Brand 0.34